LinMot®
System Overview1. Example: Online specification of an exact reference curveAn higher-level control system outputs a reference curve online for the motor to follow exactly. Solution: Operating mode‘ analog’ without limiting filter settings.PC/ PLC‘ analog out’ LinMot® P t s s LinMot® E‘ analog out’ mode:‘ analog’
t
2. Example: Online specification of any reference curveAn higher-level control system outputs position set values online for the motor to follow smoothly. Solution: Operating mode‘ analog’ with vmax/amax filter activated.‘ analog out’ PC/ PLC t s s t aamax
mode:‘ analog’
LinMot® P
‘ analog out’
LinMot® E
t-amax
3. Example: Digital selection between two set valuesFollowing a digital high/low signal from a PLC, the motor moves between two given positions with presettable maximum acceleration and speed. Solution: Operating mode:‘ Two Point’ . Acceleration limiter and speed limiter set to the desired maximal values.‘ digital out’high
low
t s PC/ PLC t v s LinMot® E t LinMot® P‘ digital out’ mode:‘ position’ two
vmax
-vmax
aamax
t-amax
User Manual V1.01
3-6
Sulzer Electronics AG
非常好的直线电机样本
LinMot®
System Overview4. Example: Digital selection between two reference curvesFollowing a trigger signal from a PLC, the motor moves between two given position following predefined trajectories. Solution: Operating mode:‘ Trigger Curve’ . Acceleration limiter and speed limiter set to the desired maximal values.‘ trigger out’high
low
t s PC/ PLC t v s LinMot P®
mode:‘ position’ two
‘ trigger out’ LinMot® E
vmax
t-vmax
aamax
t-a max
5. Example: Periodical movement sequenceThe motor executes a previously defined curve cyclically with a given frequency.high
‘ digital out’ PC/ PLC t s s LinMot® P‘ digital out’ LinMot® E mode:‘ continuous’
Solution: Operating mode:‘ Continuous Curve’ . Acceleration limiter and speed limiter set to the desired maximal v
alues.
low
t
6. Example: Synchronization on a speed valueA linear movement should be executed from a particular point and with a previously defined speed. Solution: Operating mode:‘ Analog’ Two,’ Position’ or‘ Trigger Curve’ . The reference position should be set in such a way, that the speed limiter will be active in the synchronization range.
‘ digital out’high
PC/ PLClow
t s LinMot® P s t v‘ digital out’
ssync
mode:‘ continuous’,‘ position’ two or‘ curve’
LinMot® E
vsync
t
User Manual V1.01
3-7
Sulzer Electronics AG
非常好的直线电机样本
3.6.3 Connection to higher-level control systems
The electronic units LinMot® E can be controlled by higher-level control systemsdirectly by means of analog or digital input/output signal lines. The necessaryparameterisation is done with the LinMot® Talk software via an RS-232 working via CAN-bus or RS-232 is also possible on specific customer request.
Figure 3-4: Connecting LinMot® to an higher-level control system
非常好的直线电机样本
3.7 Protection and error behavior
3.7.1 Internal protection functions System Overview
The integrated sensors and complex monitoring programs allow the detection andhandling of thermal overloading of the LinMot® E and P components by means ofwarning and/or error messages. There is further the possibility to monitor the voltagesupply of the LinMot® E electronic units for overvoltage and undervoltage. If thehigher-level control system does not respond to the warning and error messages, theactuators will be shut down for safety reasons.
3.7.2 Monitoring functions
The so-called following error monitoring and the position range monitoring offer twopowerful functions for the monitoring of the actual movement processes.Following error monitoringPosition range monitoring
3.7.3 Emergency stop possibilities
From the point of view of the higher-level control system there are two ways to handle® the LinMot actuators in case of an emergency stop:
With the so-called FREEZE signal the drives can be stopped and maintained in
their current position. The movement is resumed when the FREEZE signalbecomes inactive again.
By means of the STOP signal the drives can be driven to a predefined emergency
stop position or shut down.
3.7.4 Emergency stop through supply interruption
As the LinMot® electronic units feature separate supplies for the signal circuitry andthe power circuitry, an emergency stop can also be forced by directly interrupting thepower supply to the power circuits. As long as the signal circuitry remains powered,the initialization and actual position of the LinMot® P actuators are not lost. Thereforeit is possible to resume operation without needing to re-initialize the drives.