力士乐 比例换向阀
Electrical connection
3) Recommended pre-fuse
Characteristics medium time-lag according to DIN 41571, 1.25 A
Suppressor diode 47 V, 1.5 kW
+( )
(+)
DC/PWM
The type-examination tested valve solenoid is equipped with a terminal box and a type-tested cable gland.The connection is polarity-independent.
Important:
Corresponding to the rated current, a fuse according to DIN 41571 and EN / IEC 60127 has to be connected ahead of every valve solenoid (max. 3 x I rated ).
The shut-off threshold of the fuse has to match the prospec-tive short-circuit current of the supply source.
The prospective short-circuit current of the supply source may amount to a maximum of 1500 A.
This fuse may only be installed outside the explosive area or must be of an explosion-proof design.
Cable gland Type approval II 2G Ex e IIC Gb Threaded connection
M20 x 1.5Protection class according to EN 60529IP66 1)
Line diameter mm 9 (11)
Sealing
Outer sheath sealing
Connection line Line type
Non-armored cables and lines (outer sheath sealing)Temperature range
°C –30 … > +110
1) If installed properly
Properties of the connection terminals
Position Function
Connectable line cross-section 1Operating voltage connection
Single-wire 0.75 … 2.5 mm 2Finely stranded 0.75 … 1.5 mm 22Connection for protective earthing conductor Single-wire max. 2.5 mm 2Finely stranded max. 1.5 mm 23
Connection for potential equalization conductor
Single-wire 4 … 6 mm 2Finely stranded 4 mm 2