力士乐比例换向阀(14)
时间:2025-07-14
时间:2025-07-14
力士乐 比例换向阀
Dimensions size 16 (dimensions in mm)
1Main valve
2Pilot control valve
3Proportional solenoid "a"4Proportional solenoid "b"5Terminal box
6Plug screw for valves with one solenoid 7Name plate for pilot control valve 8Name plate for main valve
9Pressure reducing valve (always available)10Identical seal rings for ports P, A, B and T 11Identical seal rings for X and Y
12
Machined valve contact surface valve contact face, porting pattern according to ISO 4401-07-07-0-05 (X, Y as required)
Deviating from the standard:
– Ports P, A, B and T with Ø 20 mm 13Locating pin 12
Required surface quality of the
valve contact surface
Subplates
G 172/01 FE/ZN (G3/4) G 172/02 FE/ZN (M27 x 2)G 174/01 FE/ZN (G1)
G 174/02 FE/ZN (M33 x 2) G 174/08 FE/ZN (flange)with dimensions as in the data sheet 45056 must be or-dered separately.
Valve mounting screws
For reasons of stability, exclusively use the following valve mounting screws:
2 hexagon socket head cap screws ISO 4762-M6x60-10.9-flZn-240h-L
(friction coefficient total: 0.09-0.14 according to VDA 235-101)(must be ordered separately)
4 hexagon socket head cap screws ISO 4762-M10x60-10.9-flZn-240h-L
(total friction coefficient: 0.09-0.14 according to VDA 235-101)(must be ordered separately)Important:
Subplates are no components in the sense of directive 94/9/EC and can be used after the manufacturer of the overall system has assessed the risk of ignition.
The G...FE/ZN versions are free from aluminum and/or mag-nesium and galvanized.