力士乐 比例换向阀
Technical data
general
Installation position Any, preferably horizontal Storage temperature range °C –20 … +50Ambient temperature range °C –20 … +60 Weight, maximum
Size 10kg 10Size 16kg 16Size 25kg 21Size 32
kg 45
Surface protection
Galvanized coating
hydraulic
Size
Size
10
16
25
32
Operating pressure range
Pilot control valve Pilot oil supply external or internal
bar 30 … 31530 … 35030 … 35030 … 350Main valve bar Up to 315Up to 350Up to 350Up to 350Return flow pressure
Port T
(external pilot oil return)bar Up to 315Up to 250Up to 250Up to 150Port T
(internal pilot oil return)bar Up to 30Up to 30Up to 30Up to 30Port Y
bar Up to 30Up to 30Up to 30Up to 30Pilot volume
for switching process 0 → 100 %cm 3 1.7 4.61026.5Pilot flow at port X and Y
with stepped input signal 0 → 100 %l/min 3.5 5.5715.9Flow of the main valve l/min
Up to 170
Up to 460
Up to 870
Up to 1600
Hydraulic fluid
Mineral oil (HL, HLP) according to DIN 51524 Additional hydraulic fluids upon request!
Ignition temperature > 180 °C
Hydraulic fluid temperature range °C –20 ... +80 (NBR seals)°C –15 ... +80 (FKM seals)Viscosity range
mm 2/s
20 ... 380 (preferably 30 ... 46)
Maximum admissible degree of contamination of the hydraulic fluid
Class 17/15/12 1)Cleanliness class according to ISO4406 (c)Pilot control valve Main valve Class 18/16/13 1)
Hysteresis
%
≤ 6
1) The cleanliness classes specified for the components
must be adhered to in hydraulic systems. Effective filtra-tion prevents faults and at the same time increases the life cycle of the components. For the selection of the filters see /filter.