PDS_M-series_MQ_Controller
发布时间:2024-11-08
发布时间:2024-11-08
M-series MQ Controller
The DeltaV MQ Controller and the DeltaV I/O subsystem make rapid installation easy.
Increases productivity Easy to use
Has the flexibility to meet your needs
Introduction
The MQ Controller provides communication and control between the field devices and the other nodes on the control network. Control strategies and system
configurations created on earlier DeltaV systems can be used with this powerful controller. The MQ Controller provides all the features and functions of the MD Plus Controller, with the same amount of memory.
The control languages executed in the controllers are
described in the Configuration Software Suite product data sheet.
Benefits
Increases productivity
The MQ Controller is as quick as the MD Plus Controller and provides the same configurable memory as the MD Plus controller, while Enhanced Memory handling got added.The Ethernet ports are full duplex, 100MB/second maximum throughput. The results are lower CPU utilization and higher capacity for control strategies.
Self-addressing. The DeltaV controller is unique in its
ability to automatically identify itself to the DeltaV control network. When the controller is powered up, it is automatically assigned a unique address—no dip switches, no configuring—just plug and play!
Self-locating. A controller’s physical location is easy to
find. LEDs on the face of the controller can be made to flash, providing a strong visual clue.
Automatic I/O detection. The controller can identify all
I/O interface channels located on the subsystem. As soon as an I/O interface is plugged in, the controller knows the general characteristics of the field devices managed by that I/O interface. This reduces the no value engineering associated with configuration — easy!
Easy to use
Total control. The controller manages all control
activities for the I/O interface channels. It also manages all communication functions for the communications network. Time tamping, alarming, and trend objects are also
managed within the controller. The controller executes all control strategy with execution speeds up to every 100 ms.
Data protection. All online changes made to control
parameters are automatically stored for later upload into the engineering database. This way, the system always retains a complete record of all the data that has been changed online..
Cold restart. This feature provides automatic restart of
the controller in case of a power failure. The restart is completely autonomous because the entire control strategy is stored in NVM RAM of the controller for this purpose. Simply set the restart state of the controller to current conditions.
The MQ Controller
Note: To prevent process disruption during a short power
loss, an uninterruptible power supply (UPS) is available for the controller.
Has the flexibility to meet your needs
Advanced operations. The MQ Controller is equipped
to handle the DeltaV Batch option, as well as advanced control functions.
You can also use advanced control function such as
Neural and Model Predictive Control on the MQ controller.
Data pass-through. The controller is equipped with the
ability to pass smart HART information from field devices to any workstation node in the control network. This means you can take advantage of applications, such as Asset Management Solutions, that enable you to remotely manage the HART information contained in your HART or FOUNDATION fieldbus-equipped devices.
Prepares you for the future. As your system grows,
you can expand your software license to increase the number of device signal tags (DSTs) allocated to the
DeltaV controller. Begin with 50 and expand to 750 DSTs. Control strategy complexity and control module scan rates determine overall controller performance and application size. A redundant controller may be added to back up an MQ Controller online. The standby controller comes online automatically, with a bumpless transition. For more information, refer to the I/O Redundancy product data
sheet.
Mounting. This plug-and-play system structure provides
modular system growth with a single controller and can be mounted in a Class 1, Div 2 or ATEX Zone II
1
environment. Refer to the System Power Supplies and I/O Subsystem Carriers product data sheets for additional information.
Designed to support legacy migration
Advanced operations. The MQ controller provides the
DeltaV platform to migrate PROVOX and RS3 controllers, and also supports the PROVOX and RS3 Migration I/O interfaces.
The existing PROVOX I/O remains in place using the migration I/O interface to PROVOX with support of up to 750 real I/O signals. Serial datasets are migrated to DeltaV serial cards and all virtual I/O are no longer
required due to the direct module references possible in the DeltaV system.
RS3 system migrations to the DeltaV system are fully supported with MQ Controllers and the migration I/O interface for RS3.
1
Refer to Zone 2 installation instructions (12P2046) and/or Class 1 Division 2 installation instructions (12P1293) for details.
Specifications
M-series MQ Controller
Ordering Information
Prerequisites
For each controller you will need to select the
mounting carrier. Please refer to the I/O Carrier product data sheet for details.
Each controller requires a dedicated system power
supply. Please refer to the Power Supplies product data sheet for details.
The MQ controller requires v12.3.or later DeltaV
software.
To locate a sales office near you, visit our website at: http:///DeltaV Or call us at:
Asia Pacific: 65.6777.8211
Europe, Middle East: 41.41.768.6111 North America, Latin America: +1 800.833.8314 or +1 512.832.3774
© Emerson Process Management 2013. All rights reserved. For Emerson Process Management trademarks and service marks, go to: http:///home/news/resources/marks.pdf.
The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warrantees or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and conditions, which are available on request. We reserve the right to modify or improve the design or specification of such products at any time without notice.
下一篇:中房地产2013年半年度报告