B32686-A334-M中文资料(8)
发布时间:2021-06-07
发布时间:2021-06-07
元器件交易网
B32682…B32686
Technical data
Climatic category
in accordance with IEC 60068-1Lower category temperature TminUpper category temperature TmaxDamp heat testLimit values after damp heat test
55/100/56
MFP
55 °C+ 100 °C
56 days/40 °C/93% relative humidityCapacitance change | C/C|
Dissipation factor change tan δInsulation resistance Ris
or time constant τ = CR Ris0,5 VR; 40 °C 1 10 9/h = 1 fit
For a conversion table for other operating conditions and tem-peratures, refer to chapter “Quality assurance”, page327.
≤ 2 %
≤ 1,0 10 3 (at 10 kHz) ≥ 50 % of minimum as-delivered values
Reliability:
Reference conditionsFailure rate
Service life
Failure criteria:Total failure
Failure due to variation of parameters
200 000 h
Short circuit or open circuitCapacitance change | C/C|Dissipation factor tan δInsulation resistance Ris
or time constant τ = CR Ris2,0 VR, 2 s
T ≤ 85 °C: VC = 1,0 VR or 1,0 Vrms
> 10 %
4 upper limit values
< 1500 M (CR ≤ 0,33µF) < 500 s(CR > 0,33µF)
DC test voltage
Category voltage VC
Operation with dc voltage orac voltage Vrms up to 1 kHzDissipation factor tan δ (in 10 3)at 20 °C
(upper limit values)
CR ≤ 0,1 µF
at
1 kHz10 kHz100 kHz
–0,41,0
CR > 0,33 µF30 000 s
CR > 0,1 µF0,40,5–
Insulation resistance Ris
or time constant τ = CR Risat 20 °C, rel. humidity ≤ 65 % (minimum as-delivered values)
CR ≤ 0,33 µF100 G
185
12/00
下一篇:电视排行榜