INPUT SPECIFICATIONS

Input Voltage Range 90-264 VAC

Frequency Range

47-63 Hz Power Factor Correction 0.96 to 0.98 Inrush Current, typ: 30A @ 115VAC

60A @ 230VAC *

OUTPUT SPECIFICATIONS

Voltage and Current (Note 6) See Selection Chart

Line Regulation (Note 8) See Selection Chart Load Regulation (10%-FL, Note 7) Singles: ± 0.5%, typ Duals: ±3/5%, typ Preset Accuracy (Note 9) ±1%, typ DC Voltage Adjust (typ) ±6%, typ Temperature Coefficient ±0.05%/°C Ripple/Noise (Notes 1, 3, 10) See Selection Chart Over Voltage Protection Latching, Auto Recover after fault condition is removed * Short Circuit Protection Latching, Auto Recover after fault condition is removed * Hold Up Time 20mS, typ (Nom I/P, FL)

GENERAL SPECIFICATIONS

Isolation (Note 4) I/P-O/P: 4000VAC I/P-Ground: 2000VAC O/P-Ground: 500 VAC Efficiency

75%, min.

Switching Frequency 67Khz, (fixed, typical) Safety

UL,TUV, CB, CE

All specifications are typical at nominal input, full load, and 25°C unless other-wise noted

* These are stress ratings. Exposure of the devices to any of these conditions

may adversely affect long term reliability. Proper operation under conditions other than the standard operating conditions is neither warranteed nor implied.

ENVIRONmENTAL SPECIFICATIONS

Oper. Temperature -10 to +70°C

(See Derate Curve) Storage Temperature -25 to +85°C *

Relative Humidity 0% to +95%, non-cond * EMC EN55011 Class B MTBF 270,000 Hrs

Mil Std 217, 25°C

PHYSICAL SPECIFICATIONS

Size

3.2” x 5.5” x 1.6” Construction Enclosed DIN Rail Weight

1.4 lb, (635g)

NOTES

1. All measurements should be made directly at the terminals of the power supply

2. All specifications typical @ 25°C, unless otherwise noted, at nominal line and load.

3. Ripple and noise dependent upon output voltage as specified per particular model.

4. Isolation for up to 1 minute duration.5. Specified for free air convection cooling.

6. Minimum load is not required for proper operation.

7. Load Regulation is measured by change ±40% of measured output load from 60% full load, with the other output set to 60% full load.

8. Line Regulation measured from 90-264VAC. 100VAC minimum required for full load start.

9. Preset Accuracy measured at nominal load, 120VAC input.

10. O/P Noise measured directly at the pins/terminals at nominal load, 0.1uF bypass and 47uF electrolytic, pk-pk @ 20MHz bandwidth.

Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications.

ASTRODYNE USA: 1-800-823-8082ASTRODYNE PACIFIC: 886-2-26983458ASTRODYNE EUROPE: 353 51 561060