射线检验程序(8)
时间:2025-02-24
时间:2025-02-24
射线检验程序
S指X射线的FFD,γ射线的SFD
Geometric unsharpness of the radiograph shall not exceed the following:
射线的几何不清晰度不能超过下列要求:
Material材料 Ug几何不清晰度
Inches 最大(英寸) Thickness, Inches厚度(英寸) Maximum,
Under 2 0.020
2 through 3 0.030
Over 3 through 4 0.040
Greater than 4 0.070
Note: Material thickness is the thickness on which the penetrometer is based.
备注:材料厚度指像质计放置位置的材料厚度。
6.3.2 SENSITIVITY 灵敏度
Sensitivity of the radiographs shall comply with AWS D1.1 and Owner´s specification
底片的灵敏度应满足AWS D1.1及业主规格书的要求
6.3.3 FILM DENSITY 底片黑度
Film density will be the following range:
底片黑度应在下列范围内
For X-ray source: 1.8~4.0 X 射线1.8~4.0
For gamma-ray source: 2.0~4.0 伽玛射线 2.0~4.0
6.3.4 散射射线
Wherever necessary 3mm thick lead sheet shall be placed behind the film cassette to prevent scattered radiation from fogging the film. if be needed.
如有必要,应当在胶片暗袋的背面放置3毫米厚的铅板,以减小被散射线对胶片的影响。
6. 4 RADIOGRAPHIC PROCEDURES射线程序
下一篇:多目标规划2