电缆检测常用数据(7)
发布时间:2021-06-06
发布时间:2021-06-06
埃克森集团质检参考材料
护套(不等截面普通力缆)
截面1.52.54610162535507095120150185240300400
3+1结构
非铠装外护套
铠装内护
外护
3+2结构
非铠装外护套
铠装内护
外护
4+1结构
非铠装外护套
铠装内护
外护
电缆外径与护套厚度的关系(近似)
护套前直径
护套厚度
护套前直径
护套厚度
1.81.81.81.81.81.81.81.81.92.02.22.32.42.62.83.0
1.21.21.21.21.21.21.21.21.21.21.21.31.41.51.61.7
1.81.81.81.81.81.81.81.92.02.12.32.42.62.72.9
1.81.81.81.81.81.81.81.92.02.22.42.52.62.83.13.3
1.21.21.21.21.21.21.21.21.21.31.41.51.51.71.81.9
1.81.81.81.81.81.82.02.02.22.32.52.72.83.03.33.5
1.81.81.81.81.81.81.81.92.02.22.42.62.72.93.23.4
1.21.21.21.21.21.21.21.21.21.31.41.51.61.71.82.0
1.81.81.81.81.81.82.02.12.22.42.62.72.93.13.43.6
≤24.224.3-27.127.2-29.930.0-32.832.9-35.735.8-38.538.6-41.441.5-44.244.3-47.147.2-49.950.0-52.852.9-55.755.8-58.558.6-61.461.5-64.264.3-67.167.2-69.9
1.81.92.02.12.22.32.42.52.62.72.82.93.03.13.23.33.4
70.7-72.872.9-75.775.8-78.578.6-81.481.5-84.284.3-87.187.2-89.990.0-92.892.9-95.795.8-98.598.6-101.4
3.53.63.73.83.94.04.14.24.34.44.5
橡套电缆(GB5013-1997)
护套
YC
1.0
一芯二芯三芯四芯五芯
1.31.41.51.6
1.51.41.51.61.71.8
2.51.41.71.81.92.0
41.51.81.92.02.2
61.62.02.12.32.5
101.83.13.33.43.6
161.93.33.53.63.9
YCW
252.03.63.84.14.4
4.14.4352.2
450/750V
502.4
702.6
952.8
1203.0
1503.2
1853.4
2403.5
3003.6
YZ
0.75
300/500V
1.0
1.5
2.5
0.8
4.54.8
4.85.2
5.35.9
6.0
6.5
0.90.91.0
0.90.90.91.0
1.01.01.11.1
1.01.11.11.2
护套厚度计算方法:轻中型ts=0.085Df(护套前外径)+0.45
重型ts=0.13Df+0.75(线芯截面小于等于6mm2)ts=0.11Df+1.8(线芯截面大于6mm2)
硅橡胶电缆(Q/AHCW12-2001)
护套厚度计算方法:ts=0.085Df(护套前外径)+0.45(Df>13mm)
ts=1.5(Df≤13mm)
高温(聚四氟乙烯)电缆(Q/AL.22-1998)
护套厚度计算方法:普通型ts=0.025Df(护套前外径)+0.50
屏蔽和铠装型ts=0.035Df(护套前外径)+0.50