NSCSSNN100PDUNV;NSCDRRN030PDUNV;NSCSANN015PAUNV;NSCDANN100PA(3)
发布时间:2021-06-06
发布时间:2021-06-06
8
1. Absolute maximum ratings are the extreme limits the device will withstand without damage.
2. Ratiometricity of the sensor (the ability of the device output to scale to the supply voltage) is achieved within the specified operating voltage. 3. Incorrect application of supply voltage or ground to the wrong pin may cause electrical failure.
4. The specified temperature range is the temperature range over which the sensor will produce an output proportional to pressure within the
specified performance limits.
5. Accuracy: The maximum deviation in output from a Best Fit Straight Line (BFSL) fitted to the output measured over the pressure range at
25 °C [77 °F]. Includes all errors due to pressure non-linearity, pressure hysteresis, and non-repeatability.
6. Full Scale Span (FSS) is the algebraic difference between the output signal measured at the maximum (Pmax.) and minimum (Pmin.) limits of
the pressure range. (See Figure 1 for ranges.)
7. Life may vary depending on specific application in which sensor is utilized. 8. Contact Honeywell Customer Service for detailed material information.
Honeywell Sensing and Control 3
上一篇:电控液力自动变速器
下一篇:生物技术的安全性及其影响