ABB Mag Master Flow Transmitter- ABB电磁流量传送计(4)
发布时间:2021-06-08
发布时间:2021-06-08
Electromagnetic Flowmeter
MagMaster – Water & Waste Water Version
SS/MAG/WWIssue 20
Easy, Low-cost Installation
MagMaster sensors' rugged and robust construction ensure along, maintenance-free life under the arduous conditionsexperienced in the water and waste water industry. The sensorsare fully submersible, meeting the requirements of IP68(NEMA6P) enabling installation in flooded chambers or meteringpits.
MagMaster sensors in all sizes are buriable. Installation merelyinvolves excavating to the underground pipe, fitting the sensor,cabling back to the transmitter and then backfilling the hole. Nometering chambers or pits are required so the installation issimple, fast and low cost.
Underground Installation of MagMaster
International Approvals
Alternative versions of MagMaster are available for generallocations with FM Approval and for Hazardous Area locations toATEX, FM and CSA Standards. A brief summary of theseHazardous Area versions is given below, covering the safetydesignation inside the pipe. No external safety barriers arerequired.
SENSORINSIDE PIPETRANSMITTER LOCATION
FM & CSA HAZARDOUS AREA APPROVAL – CLASS 1, DIV. 2, GROUPS A B C DFM APPROVED
INTRINSICALLY SAFE ELECTRODES
CSA CERTIFIEDCSA CERTIFIED
NON INCENDIVE
REMOTE ONLY IN HAZARDOUS AREA
INTEGRAL AND REMOTE IN HAZARDOUS AREAREMOTE ONLY IN HAZARDOUS AREA
ATEX — II 2 (i) G EEx e m ia IIC T4ZONE 1
ZONE 0
REMOTE TRANSMITTER IN SAFE AREA
4