Technical Data Sheet
Infrared Remote-control Receiver Module
Features
High shielding against electric field disturbance. Low voltage and low power consumption. Very small sizes.
External dimensions 5.10(L)*4.60(W)*1.45(H)mm. High immunity against ambient light. Photodiode with integrated circuit. TTL and CMOS compatibility. High sensitivity. Top-received SMD.
Suitable burst length ≧10 pulses/burst.
RoHS refer to IRM-Vxxx,Hxxx series SGS report Pb free.
Descriptions
The device is a miniature SMD type infrared remote control system receiver that has been developed and
designed by utilizing the most updated IC technology. The PIN diode and preamplifier are assembled on PCB, the epoxy package is designed as an IR filter. The demodulated output signal can directly be decoded by a microprocessor.
Applications
1. Optical switch
2. Light detecting portion of remote control
AV instruments such as Audio, TV, VCR, CD, MD, etc. Home appliances such as Air-conditioner, Fan , etc. The other equipments with wireless remote control. CATV set top boxes Multi-media Equipment
Device Selection Guide
PART
Metal case
SPCC
Silver white
车载贴片式接收头规格书
EVERLIGHT一级代理 赵S Mob:13713906778 QQ:350843780 E-mail:OPTO_IRM@126.COM
车载贴片式接收头规格书
Available Types For Different Carrier Frequencies
Type
Carrier Frequencies (Typ)
Absolute Maximum Ratings (Ta=25℃)
Notice
Supply Voltage Operating Temperature Storage Temperature
Vcc Topr Tstg
6 -25 ~ +80 -40 ~ +85
℃ ℃
Recommended Operating Condition
Supply Voltage Rating: Vcc 2.7V to 5.5V
Electro-Optical Characteristics (Ta=25℃ , Vcc = 3V)
Condition
Supply Current Peak Wavelength Reception Distance Half Angle(Horizontal) Half Angle(Vertical) High Level Pulse Width Low Level Pulse Width High Level Output Voltage Low Level Output Voltage
Icc λp L0 L45 Θh Θv TH TL VH VL
mA No signal input
deg At the ray axis *1
μs μs At the ray axis
*2
Notes:
*1:The ray receiving surface at a vertex and relation to the ray axis in the range of θ= 0° and
θ=45°.
*2:A range from 30cm to the arrival distance. Average value of 50 pulses.
车载贴片式接收头规格书
The Notice of Application:
Transmission remote control signal consist of four parts: Encode Part, IR Transmitter Source, IRM device, Decode Part
1. When IRM-H2xxT code select frequency, it need to well understand the center system of encode part.
2. Strong or weak light of IR Transmitter can affect distance of transmission. 3. Minimum Burst Length Tburst (number of pulses per burst) : 10 cycles
4. It needs to ensure the translation range of decode part if it is applied to the pulse-width range.
If the above items hardly assure of its application, it’ll cause NG(no good) message from the edge of signal.
Note: This model might not work well with RCA code.
Test Method:
The specified electro-optical characteristics is satisfied under the following Conditions at the controllable distance. cMeasurement place
A place that is nothing of extreme light reflected in the room. dExternal light
Project the light of ordinary white fluorescent lamps which are not high Frequency lamps and must be less then 10 Lux at the module surface. (Ee≦10Lux)
eStandard transmitter
A transmitter whose output is so adjusted as to Vo=400mVp-p and the output
车载贴片式接收头规格书
Application Circuit:
RC Filter should be connected closely between Vcc pin and GND pin.
车载贴片式接收头规格书
EVERLIGHT ELECTRONICS CO.,LTD.
Fig.-6 Output Pulse Length vs. Arrival Distance Fig.-7 Arrival Distance vs. Supply Voltage
车载贴片式接收头规格书
Typical Electro-Optical Characteristics Curves
Fig.-8 Arrival Distance vs. Ambient Temperature Fig.-9 Relative Transmission Distance
Fig.-9 Relative Transmission Distance vs. Center Carrier Frequency
车载贴片式接收头规格书
Reliability Test Item And Condition
The reliability of products shall be satisfied with items listed below. Confidence level:90% LTPD:10%
Reflow Terms: JEDEC Level 4 Specification Drying; Temp.:125℃ 24hrs Æ Moisture 30℃ / 60% RH 96hrs Æ Reflow Temp.: 260℃±5℃ 10sec, 3 times
Note:
1. Not sooner than 15 minutes and not longer than 4 hours after removal from the temperature/humidity chamber.
2. The time between reflow shall be 5 minutes minimum and 60 minutes maximum.
车载贴片式接收头规格书
Recommended method of storage
Dry box storage is recommended as soon as the aluminum bag has been opened prevent moisture absorption. The following conditions should be observed, if dry boxes are not available:
Storage temperature 10℃ to 30℃ Storage humidity ≦60%RH max.
After more than 72 hours under these conditions moisture content will be too high for Reflow soldering:
In case of moisture absorption, the devices will recover to former condition by drying under the following condition:
192 hours at 40℃+5℃/-0℃ and 5%RH (dry air / nitrogen) or 96 hours at 60℃+5℃ and < 5%RH for all device containers or 24 hours at 125℃+5℃ not suitable for reel or tubes. …… 此处隐藏:3905字,全部文档内容请下载后查看。喜欢就下载吧 ……