B43304E2188M002中文资料(2)
时间:2025-07-12
时间:2025-07-12
元器件交易网
B43304
Miniaturized – 85°C
Specifications and characteristics in briefRated voltage URSurge voltage USRated capacitance CRCapacitance toleranceDissipation factor tan δ(20 °C, 120 Hz)Leakage current IL(5 min, 20 °C)Self-inductance ESLUseful life
85 °C; UR; I~max
40 °C; UR; 1,15 · I~R
> 2 000 h> 100 000 h200 … 450 VDC
1,15 · UR (for UR ≤ 250 VDC)1,10 · UR (for UR ≥ 400 VDC)82 …2200µF± 20 % M
UR ≤ 250 V: tan δ ≤ 0,15 UR ≥ 400 V: tan δ ≤ 0,20CRURö0,7
IL≤0,3µA æ+4µA------ -------è-µFVø
Approx. 20 nH
Requirements: C/C
tan δ IL
≤ ± 30 % of initial value
≤ 3 times initial specified limit≤ initial specified limit
Failure percentage:≤ 1 %Failure rate:≤ 100 fit (≤ 100 · 10–9/h)
(for definiton “fit”, refer to chapter “Quality”, page62)
Load life test85 °C; UR; I~R
2000 h
Post test requirements: C/Ctan δIL C/Ctan δIL
≤ ± 20 % of initial value
≤ 2 times initial specified limit≤ initial specified limit≤ ± 10 % of initial value
≤ 1,3 times initial specified limit≤ initial specified limit
Voltage endurance test85°C; UR
2000 h
Post test requirements:
Vibration resistance
IEC climatic category
Detail specificationSectional specification
To IEC 60068-2-6, test Fc:
displacement amplitude 0,35mm, frequency range 10 … 55Hz,acceleration max. 5g, duration 3 × 2 hTo IEC 60068-1:
UR ≤ 250 VDC:40/085/56 (– 40°C/+ 85°C/56 days damp heat test)UR ≥ 400 VDC:25/085/56 (– 25°C/+ 85°C/56 days damp heat test)Similar to CECC 30301-806IEC 60384-4